Que tal,
Les traigo solucion al siguiente problema.
Cuando en un servidor de UM se detiene de repente o no inicia, y cuando revisan el visor de eventos les regresa lo siguiente
Log Name: Application
Source: MSExchange Unified Messaging
Date: 1/18/2014 11:58:14 AM
Event ID: 1430
Task Category: UMCore
Level: Error
Keywords: Classic
User: N/A
Computer: EXCHUM.ucblog.mx
Description:
The Unified Messaging server shut down process umservice (PID=4548) because a fatal error occurred.
Event Xml:
<Event xmlns=»http://schemas.microsoft.com/win/2004/08/events/event»>
<System>
<Provider Name=»MSExchange Unified Messaging» />
<EventID Qualifiers=»49156″>1430</EventID>
<Level>2</Level>
<Task>2</Task>
<Keywords>0x80000000000000</Keywords>
<TimeCreated SystemTime=»2015-01-22T16:58:14.000000000Z» />
<EventRecordID>3876459</EventRecordID>
<Channel>Application</Channel>
<Computer>EXCHUM.ucblog.mx</Computer>
<Security />
</System>
<EventData>
<Data>umservice</Data>
<Data>4548</Data>
</EventData>
</Event>
Lo que tienen que hacer para solucionar este problema, es revisar que se encuentre instalado Desktop Experience en los features del Servidor. Cuando termine de instalar deben de reiniciar el servidor.
Espero les sea de ayuda.
Deja un comentario